Tested on model LFH3500 with MModal. If the device isn’t passed through to the VDA as a Generic USB device, the buttons on the microphone will not function.
Citrix Policy
Apply these Citrix policies to the VDA:
- Client USB device redirection = Allowed
- Client USB device redirection rules = Allow: VID=0911 PID=0C1C #Philips SpeechMike III
- Client USB device optimization rules = Mode=00000001 VID=0911 PID=0C1C #Philips SpeechMike III
- Mode=00000001 disables optimization
Group Policy
Apply these group policy settings to the connecting client workstation:
- Computer Configuration/Policies/Administrative Templates/Citrix Components/Citrix Receiver/Remoting client devices/Generic USB Remoting
- Existing USB Devices
- Enabled
- When desktop starts = Connect all available USB devices
- New USB Devices
- Enabled
- When a USB device is inserted = Connect the USB Device
- USB Device Rules
- Enabled
- USB Device Rules = Allow: VID=0911 PID=0C1C #Philips SpeechMike III;
- Existing USB Devices
Client Registry
Apply these registry entries to the connecting client workstation:
- [HKEY_LOCAL_MACHINE\SOFTWARE\WOW6432Node\Policies\Citrix\ICA Client\GenericUSB]
“EnableForceRestartForHID”=dword:00000001- Necessary if the device could be potentially in use prior to connecting to the VDA, otherwise a warning will appear to the user
- [HKEY_LOCAL_MACHINE\SOFTWARE\WOW6432Node\Policies\Citrix\ICA Client\GenericUSB\Devices\VID0911 PID0C1C]
“AutoRedirect”=dword:00000001- Disabled optimization on the client